7.2.3.2

switchport access vlan

Description
With this command, you assign an VLAN to an interface and configure the port VLAN identifier
(PVID) for it.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
switchport access vlan <vlan-id(1-4094)>
The parameter has the following meaning:
Parameter
vlan-id
Result
The Interface is added to the VLAN as an untagged port and the corresponding VLAN ID is
set.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
All frames (with and without VLAN variables) are accepted
Only frames with VLAN variables are accepted
Description
Number of the addressed VLAN
Network structures
7.2 VLAN
Range of values / note
1 ... 4094
291