Requirement
● The PLUG is formatted.
● You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameter assignment:
write
Result
The current device configuration has been copied to the formatted PLUG.
5.1.3.5

presetplug

Description
With this command, you create a PRESET-PLUG. Apart from the configuration data, a
PRESET-PLUG also contains the firmware version of the creating device. The PRESET PLUG
is write-protected.
I a device starts with a PRESET-PLUG an upgrade/downgrade of the firmware is performed
if there is a different firmware version on the device. This is indicated by the red LED flashing
(flashing interval: 2 sec on/0.2 sec off). Afterwards the device is restarted and the device
configuration incl. users and certificates on the PRESET-PLUG is transferred to the device.
To make the PLUG writable again, call the command factoryclean.
Requirement
● The PLUG is formatted.
● There is a device configuration on the PLUG.
● You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameter assignment:
presetplug
Result
The firmware of the executing device is written to the PLUG and write-protected.