Security and authentication
11.3 WLAN
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with ethernet
Result
The communication option is disabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the vap communication with ethernet command.
See also
vap communication with ethernet (access point) (Page 537)
11.3.5.14

vap inter-ap-blocking allowed address

Description
With this command you specify which SCALANCE W700 devices are accessible to the clients.
Note
The command is only available when the following requirements are met:
● Access point mode
● The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
538
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08