Functions specific to SCALANCE
5.6 iPCF-MC
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call the command without parameter assignment:
no wlan ipcf-mc
Result
iPCF-MC is disabled.
Further notes
You enable iPCF-MC with the wlan ipcf-mc command.
You display the setting with the show wlan ipcf-mc command.
5.6.2.3

wlan ipcf-mc protocol-support (access point)

Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
● iPCF-MC is enabled with the aid of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5 907-8PA00)
– W740 iFeatures (MLFB 6GK5 907-4PA00)
wlan ipcf-mc protocol-support (access point)
Description
With this command, you enable the optimized support of PROFINET or Ethernet.
Frames with the selected protocol are preferred.
Requirement
The SCALANCE W700 device is in access point mode.
You are in the WLAN configuration mode.
The command prompt is as follows:
142