11.3.2.13
vap inter-ap-blocking refresh time
Core statement
This command specifies the update interval for the ARP table. The default for this value is 60
seconds.
Note
The command is only available when the following requirements are met:
● Access point mode
● The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the WLAN Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-wlan)#
Syntax
Call up the command with the following parameters:
vap inter-ap-blocking refresh time <seconds(30-300)>
The parameters have the following meaning:
Parameter
seconds
Result
The ARP table is updated when the set time elapses.
11.3.3
Commands in the WLAN Interface configuration mode
This section describes commands that you can call up in the WLAN Interface Configuration
mode. Depending on the Interface selected, various command sets are available.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Update interval for the ARP
table in seconds.
Range of values / note
30 ... 300
Security and authentication
11.3 WLAN
511