hit counter script

Wlan Antenna Type - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.1 WLAN
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan antenna gain-5GHz <index(1-3)> <dBi (0-30)>
The parameters have the following meaning:
Parameter
index
gain value
Result
The antenna gain is specified.
Further notes
You show the set antenna gain with the show wlan antennas <wlan 0/X> command.
7.1.5.16

wlan antenna type

Description
With this command, you specify which antenna type is connected to the relevant antenna
connector.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan antenna type {show-types | <index(1-3)> <antenna-index>}
222
Description
Antenna connector
Antenna gain in decibels isotrop‐
ic (dBi)
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
1...3
0 ... 30
0 = antenna is not connected