hit counter script

Sftp Server - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Requirement
● The name of the file is specified
● You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
sftp save {showfiles|filetype<filetype>}
The parameters have the following meaning:
Parameter
showfiles
filetype
filetype
Result
The file types are displayed or the file is copied.
Further notes
You configure the name of the file with the sftp filename command.
With the "show loadsave files" command, you can display the file types.
4.2.5.9

sftp server

Description
With this command, you configure the access to an SFTP server.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
sftp server {ipv4 <ucast-addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>}
[port <tcp port (1-65535)>] [user <username>] [password <password>]
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Shows the available files
Keyword for a file type to be loaded
Name of the file type
Configuration
4.2 Load and Save
Range of values / note
-
-
max. 100 characters
95