Layer 3 functions
10.1 NAT
10.1.3.12

nat timeout (Client)

Note
This command is only available in the client mode.
Description
With this command, you configure the time period for the TCP / UDP connection. If no data
exchange takes place, the TCP / UDP connection is deleted from the translation table when
this time has elapsed.
Requirement
You are now in the NAT Configuration mode.
The command prompt is as follows:
cli(config-nat)#
Syntax
Call up the command with the following parameters:
nat {tcp|udp} timeout <seconds>
The parameters have the following meaning:
Parameters
tcp
udp
seconds
Result
The period of time is configured.
Further notes
You show the NAT configuration and the translation list with the show nat command.
You delete the period of time with the no nat timeout command.
See also
show nat (Client) (Page 456)
468
Description
TCP connection
UDP connection
Period of time in seconds
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Range of values / note
-
-
1 ... 4294967295