The command prompt is as follows:
cli (config-wlan-context-x)#
Syntax
Call up the command with the following parameters:
wlan security dot1x username <string>
The parameter has the following meaning:
Parameters
string
Result
The user name is specified.
Further notes
You display the settings with the show wlan security command.
11.3.4.8

wlan security dot1x password (client)

Description
With this command, you specify the password for the RADIUS server.
When assigning the password, ASCII code 0x20 to 0x7e is used.
Note
This command is only available in the client mode.
Note
Dot1X user name and Dot1X user password
With WPA (RADIUS), WPA2 (RADIUS), EAP-TLS, EAP-TTLS and PEAP the Dot1X user name
and the Dot1X user password must be configured.
With the setting "Auto" either the certificate must be loaded or the Dot1X user name and the
Dot1X user passport must be configured.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Range of values / note
User name
Enter the user name for the RADIUS server. You specify
the corresponding password with the wlan security
dot1x password command.