hit counter script

Wlan Ipcf Scan-Mode (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Functions specific to SCALANCE
5.4 iPCF
The following points need to be taken into account when setting the cycle time. Otherwise it
may not be possible to establish stable communication.
● There is only one access point in the system; in other words, the clients move only in one
wireless cell. In this case, update times >= 16 ms are supported.
● There are several access points in the system that communicate over different channels.
The clients roam between the access points. In this case, select update times >= 32 ms.
In addition to the guide values shown above, remember that the shortest cycle time to be set
is calculated according to the formula "2 ms * max. number of nodes".
Requirement
The SCALANCE W700 device is in access point mode.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ipcf cycle-time <ms (4-512)>
The parameter has the following meaning
Parameter
ms
Result
The cycle time is configured.
Further notes
You display the setting with the show wlan ipcf command.
5.4.2.6

wlan ipcf scan-mode (access point)

Note
This command is only available with the following KEY-PLUG:
● W740 iFeatures (MLFB 6GK5 907-4PA00)
128
Description
Cycle time in millisec‐
onds (ms)
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
4, 8, 16, 32, 64, 128, 512
Configuration Manual, 09/2017, C79000-G8976-C324-08

Advertisement

Table of Contents
loading

Table of Contents