Diagnostics
12.1 Diagnostics
12.1.6.6

link

Description
With this command, you configure and enable the monitoring of the physical network
connections for cable breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
link {up|down}
The parameters have the following meaning:
Parameters
up
down
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You disable the function with the no link command.
12.1.6.7

no link

Description
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
596
Description
Only the establishment of a connection is signaled
Only a break on a connection is signaled