You show the links in the table "External User Accounts" with the show user-accounts
external command.
11.1.4.6

no user-account-ext

Description
With this command, you delete the link between a user and a role in the table "External User
Accounts".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-account-ext <user-name-ext>
The parameter has the following meaning:
Parameter
user-name-ext
Result
The link in the table "External User Accounts" has been deleted.
Further notes
You link a user with a role in the table "External User Accounts" with the user-account-
ext command.
You show the links in the table "External User Accounts" with the show user-accounts
external command.
11.1.4.7

user-group

Description
With this command you link a group with a role.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
User name
Security and authentication
11.1 User rights management
Range of values / note
Enter the name of a user.