If no parameters are specified, all configured RADIUS servers are displayed.
Result
The RADIUS server configuration is displayed.
The password cannot be read as plain language, instead asterisks * are displayed.
11.2.2

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
11.2.2.1

login authentication

Description
With this command, you enable authentication via a RADIUS server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
login authentication {radius | local-and-radius | radius-fallback-
local}
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Security and authentication
11.2 RADIUS client
489